              GDJB-802 Three Phase Secondary Current Injection Relay Test SetGDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. 
- 
              GDYZ-302 Wireless Zinc Oxide Surge Arrester TesterGDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. 
- 
              GDUD-PBI Ultrasonic Flaw Detector for Electrical EquipmentUltrasonic Flaw Detector is a non-destructive testing device used for detecting internal mechanical damages for electrical equipment. 
- 
              FCZ-IV Discharge Counter CalibratorFCZ-IV Discharge Counter Calibrator is used to verify the reliability of various arrester counter action.The reliability of counter action is very important for power system. It is an important parameter to record the number of lightning strikes of arrester in normal operation. It can provide an important basis for the personnel of power system to test the arrester. This instrument is mainly used for high voltage arrester above 35kV. 
- 
              GDUD-PTM Ultrasonic Flaw Detector For Electrical Power TowerUltrasonic Flaw Detector is a non-destructive testing device used for material defect evaluation and location, wall thickness measurement, etc. and suitable for various large workpieces and high resolution measurement requirements. 
- 
              GDYZ-302W Metal Oxide Arrester (MOA) TesterGDYZ-302W Metal Oxide Arrester Tester is is composed of a host, a detector, and an insulating rod. The host and the detector adopt wireless communication, the communication distance is 30 meters, the host can remotely open or close the clamp head of the detector to complete the test process, and the host can display the current test value and the status of the clamp head in real time. The detector uses a micro motor to drive the opening or closing of the clamp head. The clamp head is made of high-performance permalloy, which has super anti-interference ability and is hardly affected by external magnetic fields. The resolution is as high as 1uA. The detector can be connected to an insulating rod for testing of zinc oxide surge arresters on high-voltage lines. The meter can also be used as an ultra-high-precision clamp-on leakage current meter. 
- 
              GD-610B Insulator Faults DetectorThe model GD-610B is used to detect faults of insulators and locate the faults in power station, substation without cutting power. It also can be used for PD detection, corona discharge detection, discharge detection of electric equipment. 
- 
              GDJW-40B Wireless Insulator TesterGDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing. 
- 
              Online Monitoring System for Metal Oxide ArresterThere are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. 
- 
              GDYZ-301 Zinc Oxide Surge Arrester TesterGDYZ-301 Lightning Arrester Tester is the special equipment of testing zinc oxide arrester electric performance. It is suitable for testing various voltage levels zinc oxide arrester with or without electricity, thus to detect hazards inside the device caused by wet insulation or metal oxide varistor (MOV) aging. 
- 
              GDYZ-301A Zinc Oxide Surge Arrester TesterGDYZ-301A Automatic Zinc Oxide Surge Arrester Tester contains below three functions: Resistive current test Current meter calibration of monitor Counter action test of monitor 
- 
              GD-2134A Cable IdentifierThe purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. 